Small Chiller is an outstanding moveable cooling unit that ensures the cooling of different industrial applications with varying heating loads.
Are you interested in learning more about Mini Chiller System? Contact us today to secure an expert consultation!
It has a compact design to minimize the need for larger space for installation. Its small footprints occupy less space. It is a highly durable cooling system with easy installation and low maintenance costs.
Different processing machines are integrated for continuous heat dissipation as metalwork, drilling, milling and injection molding, etc.
Small Chiller Fabricated by TopChiller
Small Chiller configures heat discharging from an application by having some essential components as given below:
Compressor
A hermetic scroll compressor is the fundamental component of a refrigeration circuit that is mediated to put compression over a refrigerant to increase its temperature and pressure.
The scroll compressor contains two scrolls that rotate over each other for refrigerant compression. It is also equipped with a crankcase heater and rubber vibration isolator.
Condenser
An air-cooled condenser is preferably used for Small Chiller to dissipate the extra heat from an application collected by the refrigeration circuit.
It is featured seamless copper tubes that extend over aluminum fins. Aluminum fins are hydrophilic, ensuring protection from corrosion.
Fresh ambient air circulates over copper coils and absorbs heat from the refrigerant. After condensation of evaporated refrigerant, air releases out into the environment.
Evaporator
The evaporator is factory insulated and featured anti-freezing material optionally. The evaporator mediates the heat exchange efficiently between refrigerant and coolant.
The plate-type evaporator is preferably installed and occupies little space than the shell and tube-type heat exchanger. Refrigerant leaves evaporator with low pressure and temperature.
Axial Fans
Axial fans are equipped with drive motors and enlisted with an IP54 protection rating. Axial fans maintain the airflow rate for final heat discharge from the refrigerant.
Electric Panel
The electric panel consists of a microprocessor controller, breakers for the compressor, fan motor protection, and compressor contactors.
Small Chiller Control Panel
A Small Chiller is configured with some basic features for entailing cooling effect as given below:
Small Chiller Compressor
Small Chiller is a small-sized portable cooling unit. It is efficient in providing a cooling effect for different applications. Its working process is given below:
Step 1
It dissipates the systems heat using two fluids, coolant, and refrigerant, which circulate in the refrigeration cycle for heat release.
The plate-type heat exchanger receives the water from the required application as a coolant. Water gets hot and enters the heat exchanger by absorbing the systems heat.
Step 2
Liquid refrigerant circulates in convoluted tubes that are immersed in plates. The coolant circulates over the refrigerant and transfers its heat to the refrigerant.
Step 3
As a result, the liquid refrigerant converts into a gaseous form and leaves the heat exchanger. Chilled water moves out and enters the applications duct system to mediate the cooling effect.
Step 4
A scroll compressor further processes the evaporated refrigerant. Scroll compressor efficiently increases the temperature and pressure of the gas. The scrolls of the compressor rotate to compress the refrigerant.
Step 5
A condenser containing copper coils and aluminum fins receives the incoming refrigerant, and dissipates its heat through ambient air circulating over the condenser.
Step 6
After that, the condensed refrigerant releases pressure through the expansion valve and enters the evaporator to cool down the coolant for the next refrigeration cycle.
A Small Chiller offers a wide range of advantages for different industrial applications, especially those with little chiller installation space. These excellent advantages are given below:
Little Space for Installation
Compact design and small footprints configure the occupation of lower space for installation. It assists the industrial applications that have little room for chiller setup.
Long Service Life
The whole body is made of stainless steel material, copper coils, and aluminum fins of condenser to protect the unit from corrosion, making it durable with long service life.
Emergency Alarms for Unit Protection
In case of ups and downs in temperature, pressure, and voltage, the microprocessor unit activates the emergency alarms preventing the Small Chiller from extensive damage.
Noise Free Operation
Installation of scroll compressor ensures efficient and noise-free working of the unit.
Noise Free Small Chiller
Though Small Chiller is a compactly designed, highly reliable, and energy-efficient unit liberating system heat.
But some accessories options can be integrated to increase working efficiency as per application needs. These accessory options are:
Chilled water supply by Small Chiller assists the release of heat from an assorted number of small scale applications as given below:
Small Chiller Applications
A scroll compressor is preferably used for Small Chiller for its reliable and energy-efficient working. It consists of a crankcase heater for maintaining oil temperate. Vibration isolators ensure the noise-free working of the compressor.
The scroll compressor comprises two scrolls. One scroll rotates over the fixed scroll unit and ultimately puts compression forces over the refrigerant.
Small Chiller Scroll Compressor
A microprocessor is a controller unit of a Small Chiller that regulates the cooling operation of the chiller. It is programmed with setpoints required for the regular operation of the whole unit.
All basic features of the chiller are inserted in the microprocessor at the factory. The microprocessor displays any setpoint change either of temperature, pressure, or voltage.
The emergency alarms are integrated with microprocessor rings to alert the operator about the problem. The problem is sorted out before completely damaging any part of the Small Chiller.
The condenser is the fundamental component of the refrigeration cycle that ensures the condensation of gaseous refrigerant into the liquid phase.
The Small Chiller is mainly featured with air-cooled condensers.
Air Cooled Condenser
It is impregnated with copper coils and aluminum fins, making the condenser hydrophilic and preventing corrosion. Fresh air, good ventilation, and suitable ambient temperature trigger the installation of the air-cooled condenser.
The gaseous refrigerant with high temperature and pressure gets entered in copper coils of condenser.
At the same time, ambient air circulates over the coils. The air absorbs heat to condense it into the liquid phase as the refrigerant flows.
The liquid refrigerant gets cooled after heat liberation, leaves the condenser, and enters the evaporator to cool down the water.
Air Cooled Condenser Small Chiller
A Small Chiller is a monobloc unit set to operate with different working modes. Cooling, heating, emergency, quiet, forced operation mode, etc., are installed as per application requisites.
The heating and emergency mode of the chiller are given below:
Heating Mode
The heating mode works opposite to the cooling mode. The refrigerant gets heated in condenser coils. At the same time, the heat exchanger condenses the refrigerant by dissipating heat: the cooled water and heated refrigerant circulating in the heat exchanger in heating mode.
The refrigerant transfers its heat to circulating water. As a result, water gets heated, flows back in application ducts, and produces a heating effect.
While the refrigerant condensed back in the liquid state by releasing its heat. It again flows towards the condenser and heats up through an electric heater to continue heating.
Emergency Mode
The emergency mode turns ON in case of malfunctioning of Small Chiller. Mostly it is installed if the unit is working on heating mode with integrated electric heaters.
Emergency mode ensures the regulated working of an electric heater. When an electric heater produces enough heating required for the indoor application, it is switched off.
Small Chiller is widely used for an assorted number of applications having little space for Installation. So it is designed in compact form to take little space for Installation.
For this purpose plate-type, heat exchangers are preferably integrated with it.
The company is the world’s best Temperature Sensitive Chillers supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.
PHE
The plate-type heat exchanger contains tubes impregnated in plates occupying less space.
The refrigerant flows inside the tubing making turbulent flow for fast heat exchange between water coolant and refrigerant.
The plate heat exchanger has corrosion resistance and is impregnated with anti-freezing chemicals optionally.
Tube in Tube Heat Exchanger
A tube in the tube the heat exchange is also installed optionally based on application needs. It comprises two tubes that are coiled with each other compactly.
It helps in size reduction by occupying little space.
Heat Exchanger Used in Small Chiller
The thermostat is a temperature regulating unit of a Small Chiller. The thermostat maintains the heating or the cooling mode of the chiller at the required range.
The thermostat also maintains the temperature of the coolant.
It works on the thermal expansion principle. An increase in temperature causes a thermal expansion and triggers switches to power off.
After maintenance of temperature, the unit is turned ON for working.
The Small Chiller is charged with refrigerant in the factory. The change in refrigerant charging affects the working of the compressor.
It may get damaged or start improper working in case of overcharging or undercharging of refrigerant.
The refrigerant is discharged from the unit when maintenance or installation is required by following some basic steps as given below:
Small Chiller Environmental Friendly Refrigerant
Small Chiller works similarly to chiller of large-sized, efficiently dissipate heat from a system. But it is considered more desiring for small scale applications due to the following features:
Compact Design
It is designed so that all of its components are compactly integrated to make the compact designed structure. Compact designing assists it to be installed at a small place.
Lockable Caster Wheels
Small size and integrated caster wheels help in its easy movement and Installation. After installation, the wheels can be locked to stay at is position.
Small Footprints
Small footprints design occupy less space having the efficient cooling capacity for small-scale applications.
Lowe Space Occupying PHE
The plate heat exchanger takes less space in the Small Chiller, but its turbulence flow principle increases the rate of heat exchanging for small-scale applications.
Lockable Heavy Duty Caster Wheels for Small Chiller
Any damage or failure of the Small Chiller component may cause a disturbance in the industrial budget. By keeping in view some aspects, the service life can be increased as given below:
Check Out the Unit for Any Leakage
Make sure the monitor of the whole unit before use to find any leakage in pipes and tubes of refrigerant or coolant. Repair it if you find any leakage to prevent a significant loss.
Cut-Off Power Supply When you are Not Using Unit
If you are not using the chiller, be sure to remove the plug, cut off the power supply and place the unit in a safe place. Dust accumulation in the evaporator can decrease the service life.
Monitoring of Wiring and Voltage Adjustment
Also, monitor the whole wiring, power supply, and phase change to reverse the compressor action. Maintain the specific range of voltage supply to prevent damages by a short circuit.
Protection from Corrosion
Protect the unit from corrosion by assuring no dust accumulation and contact with other chemicals.
Some safety measures should be followed for operating Small Chiller as given below:
The Small Chiller is configured to provide a cooling effect for different industrial applications efficiently. Its working efficiency can be further enhanced by keeping in view some considerations as given below:
Daily Records
Ensure the monitoring and inspection of the whole unit daily. Make a record of components performance. Repair or replace the chiller component which you find damaging its Performance.
Maintenance and Cleaning
All the components should clean daily to prevent the accumulation of dust that may cause hindrance in performance.
Cleaning of Heat Exchanger
Make sure to clean the tubing of the heat exchanger and feature it with anti-freezing material. It will prevent tubes from rusting and ensure working efficiency.
Pre Heating of Compressor Oil
Ensure to preheat the compressor oil almost eight hours before starting the chiller to prevent mixing oil with refrigerant. In this way, the working efficiency of the compressor is increased.
Small Chiller Monitoring
Before starting operation, there is a need to keep in view some considerations for Small Chiller as given below:
Small Chiller is a small-sized cooling unit designed to deal with different heat loads of industrial applications. Some key points should be considered while sizing the chiller as given below:
Heat Load
First, inspect the heat load of your application and then select the unit that will match your heating load.
Keep a slight margin and prefer the chiller with heat load capacity more significant than your requirements.
Type of Coolant
Different coolant has different heat absorption capacity and anti-freezing feature. By considering the heat load and ambient temperature, select the coolant chiller that exactly matches your needs.
Ambient Temperature
Determine the ambient temperature and environmental conditions. If the air is clean with low ambient temperature, then select the air-cooled Small Chiller for your application.
Pump Flow Rate
Also, inspect the water pumps flow rate, match it with your application needs, and select Small Chiller with a specified flow rate to deal with your application.
A Small Chiller is installed with small-scale applications for efficiently dissipating heat, mediating the cooling effect.
But sometimes problems may occur due to malfunctioning of some parts that can be troubleshot in the following way:
The Compressor is Not Working
If the compressor is not working correctly, the problem can be due to loose wiring, shortage of power supply, or full damage to the compressor.
This problem can be resolved by re-fixing wiring, reversing the phase, or replacing the damaged compressor with a new one.
Noise Caused by Fans
If the axial fan is making heavy noise while operating, it will represent that problem is losing of fan bolts, rubbing of fan blades with shell.
The problem can be troubleshot by re-fixing bolts, adjusting blades, or replacing the fan with a new one.
Noise Caused by Compressor
Sometimes the compressor of a Small Chiller starts to make noise due to liquid slugging in the compressor or breakdown of some of its internal parts.
Replace the compressor with a new one to mitigate the noise production. Check the expansion valve and compressor sensor; repair it to troubleshoot the problem if you find failure.
No Heating Production
If heat is not dissipated from the chiller, the compressor is running. The problem can be due to refrigerant leakage or improper working of the compressor.
The heat dissipation problem is sorted out by compensating for leakage and refilling refrigerant or replacing the compressor with a new one.
Small Chiller Routine Maintenance
The Mini Water Chiller consists of a high-efficient refrigeration mini compressor with R134a coolant, the smallest condenser, plate evaporator, filter drier, drive board, and other refrigeration parts. All these refrigeration parts are well integrated with one unit, sophisticated design by our skilled engineers. It does not only facilitate installation but also assures end users have the latest micro cooling solutions.
The Mini Water Chiller is good for customers who are able to deal with system control. They want cooling subsystem modules only to integrate or assemble with their machine or equipment. The customers control board can connect with our bldc compressor driver board to control compressor speed and get the best performance they needed. We keep engineering and manufacturing up-to-date micro and portable commercial refrigeration systems for both OEM and ODM projects.
We dont display all products here. If you cant find your interests from the list, just or call us at Ph: +86-579--.
If you are looking for more details, kindly visit How a Water Chiller Works.