Aug. 26, 2024
Measurement & Analysis Instruments
There are five vital measurements that could be causing problems in your electrical distribution system that you may be missing even with a True-rms digital multimeter. While the digital multimeter is a valuable and indispensable tool for the electrical professional, it does have limitations. A multimeter may be able to alert you to one of these five issues, but be prepared to use a power quality analyzer to dig in further and uncover these hidden potential problems.
SUIN are exported all over the world and different industries with quality first. Our belief is to provide our customers with more and better high value-added products. Let's create a better future together.
Those measurements are:
1. Harmonic current
Current flow in the system at a whole number multiple frequency of the fundamental frequency. The third harmonic current is current that flows at 180 Hz (the third harmonic of 60 Hz). While harmonic currents not only distort the fundamental 60 Hz sine waves, but excessive harmonics can also cause severe overheating and reduce motor efficiency. Once identified, filters can be installed to limit harmonic effects.
2. Total harmonic distortion (THD)
A measure of how much harmonic content there is in a waveform and should not exceed 5 % of voltage for reliable operation. If maximum acceptable THD is exceeded, locate and isolate the source of the harmonics, adding filters if needed.
3. Sags and swells
A brief decrease (sag) or a brief increase (swell) in the nominal rms line voltage. Any such fluctuations in voltage can cause problems from improper operation of electronic equipment to inadvertent relay operation.
Suggested reading:If you are looking for more details, kindly visit Single-Phase Power Quality Analyzer Manufacturers.
4. Transients
Extremely short variations in voltages, often due to lightning strikes and load switching, and can cause equipment to shut down.
5. Power factor
A representation of the volt-amp loss in a system due to reactance. While poor power factor can mean utility penalty charges, the charges can often be corrected with the installation of power factor correction systems.
The importance of investing in the right set of tools to monitor power quality issues, and prevent them in the future, can't be emphasized enough. Fluke offers an extensive range of excellent power meters and other power quality analyzers for troubleshooting, preventive maintenance, and long-term recording and analysis in industrial applications and utilities.
Fluke's range of power meters includes both single-phase and three-phase power quality analyzers for predictive maintenance, quality of service compliance testing and load studies. The three classifications are:
The reliability and cost of any electrical system depends greatly on the quality of the power supplied to and consumed by the system. Poor power quality may result in improper function, overheating, accelerated wear and tear, falsely tripped circuit breakers and, in some cases, hazardous conditions. With the introduction of new electronic technologies over the last several decades, the world has placed new and more complex demands for clean and reliable power. Measuring Power Quality typically involves calculating indicators of power demand, power consumption and power cleanliness. By measuring demand and consumption, consumers can identify cost centers in their electrical infrastructures as well as engineer the electrical infrastructure required to meet those demands. By measuring cleanliness, consumers are able to avoid improper function, overheating and a plethora of other consequences of unclean power. What is power demand and how do we measure it? Power demand is the amount of average electrical energy that is consumed over some period of time by a device, machine building, etc Power Quality Analyzers, electronic instruments used to measure indicators of power quality, can average the electrical energy and display it in units of kilowatts. It is important that electrical systems are supplied with enough power to meet peak periods of demand. How does power consumption differ from power demand? Power consumption, similar to demand, is the sum of electrical usage over time. Power demand reflects an instantaneous view of electrical usage, whereas, power consumption sums the electrical usage over the same period of time. Power Quality Analyzers measure consumption in units of watthours (Wh) or kilowatthours (kWh). Most calculations of the cost of power are based on consumption and measured by $ per kWh. Once we know power consumption, we can calculate a useful metric called Power Factor. Power Factor is a ratio of the actual power used by an electrical system to the apparent power delivered by the utility. In almost all cases, the actual power used will be less than the apparent power delivered because of heat dissipation, frictional loss, work performed and other release of energy by the electrical system. We can use Power Factor to help us put a price tag on the amount of work the electrical system is performing, as well as help us install capacitors and other devices that store real energy to avoid being charged for excess apparent power. With a Power Quality Analyzer, you can calculate the Reactive Compensation, the amount of capacitive value required to correct a low Power Factor. Power cleanliness and the need to understand harmonics Power cleanliness refers to identifying and freeing power of harmonics. The concept of harmonics is a bit more difficult to understand than demand and consumption. Harmonics are a result of non-linear loads that cause irregular spikes and dips in voltage and current on an electrical system. The power provided by utility companies is delivered in the form of a constant voltage AC (Alternating Current) and takes the shape of a sine wave. Ohms law says the amount of current used by an electrical device depends on the load (inductance) of that device. If the load varies over time, so will the current. Harmonics appear when varying loads (non-linear) create short pulses of current that deform the supplied, sinusoidal current waveform, creating an arbitrary waveform. You can think of an arbitrary wave as being made up of several fundamental waveforms. The easiest illustration of an arbitrary wave is to picture two people on opposite sides of a pool who create a wave towards each other with a pool float. When the waves intersect in the middle, the result is a wave that is twice as tall. The resulting wave is made up of two fundamental waves. This illustration can be used to explain that happens when harmonics occur due to non-linear loads. The current wave becomes deformed from a perfect sine wave and peaks and valleys create un-clean power. Harmonics can cause devices to overheat, electrical wire ratings to be reduced, motors to prematurely wear and circuit breakers to falsely trip. Power Quality Analyzers have the ability to identify and analyze the fundamental harmonics that make up an arbitrary current wave. Measurements such as THD (Total Harmonic Distortion) can tell you the contribution of harmonic currents to the fundamental current required. Measured as a percentage, 10% would be a reason for concern. Another measurement called Crest Factor will indicate the level of peaking caused by harmonics. The Crest Factor is a ratio of the Peak Value / RMS Value, which in a perfect sine wave would be 1.414. Choosing a Power Quality Analyzer There are a number of different Power Quality Analyzer manufacturers such as Fluke, AEMC, Hioki and Extech. Some analyzers are designed to measure single phase systems while others are for three phase systems. Many PQAs integrate with PCs, have enhanced data logging capabilities and can produce professional reports typically requested for power quality applications. Power Quality Analyzers range in price from $ to $ with the more expensive products offering greater analysis functionality. Whatever your application or budget it is important that power quality is a factor in the design and maintenance of your electrical system. In order to reduce costs, avoid downtime, and increase the service life of your system, power quality is a force to be reckoned with.
For more information, please visit Single-Phase Power Quality Analyzer Dealers.