The engineering department shall be responsible to perform the test to determine the MOC of the contact part and non-contact part of the equipment.
Link to YOUBO
Test shall be conducted to verify that product contact part made of SS which are claimed to be SS316 are conforming to molybdenum test.
Clean the surface of contact part under test with a clean cloth.
Place of drop of the electrolyte solution on the clean surface of the component under test.
Are you interested in learning more about Molybdenum Tube? Contact us today to secure an expert consultation!
Contact the positive (+) tip of the electrode (battery) to the component surface.
Dip and rub the (-) tip of the electrode (battery) to the drop of solution placed over SS component which is under test.
The drop of test solution shall turn to persistent red color indicative of test material as SS316 or SS316L.Drop of test solution if does not turn to red color, this shall indicate material as SS304.Wipe off the drop of solution from test surface after completing the test with a cloth.
Tightly close the molybdenum test solution vial with its lid.