COOLING TOWER | Preventative Maintenance Inspections

Author: Ruby

Jul. 01, 2024

COOLING TOWER | Preventative Maintenance Inspections

A building owner should ensure a regular daily/weekly and monthly preventative maintenance schedule is applied for their cooling towers and ancillary equipment throughout the year to help and ensure:

If you want to learn more, please visit our website evapco cooling tower maintenance.

  • The risk of Legionella is managed/reduced
  • Scale and debris build-up is managed
  • The efficiency of the tower is maintained
  • Minimizing early failure of mechanical components/electrical components 
  • Reducing corrosion within the tower and on the external surfaces
  • Reduction in downtime of the tower
  • Longevity of its intended operational life

How long do cooling towers last?

15 to 20 years is the general expectation of life for an industrial cooling tower, used in a cooling process for general office buildings, etc, before the need for replacement or extensive rebuild.

This is why a good preventative maintenance regime is extremely important, as this can sometimes extend the operational life.

We have seen cooling towers that are much older than this.

How often should cooling towers be inspected?

For preventative maintenance and depending on the component, they should be inspected daily, monthly, quarterly, semi-annually, yearly. See below.

Documentation usually required to conduct the works

The following documentation would usually be a requirement prior to any works taking place to ensure it is conducted safely and correctly:

  • Previous inspection reports
  • System schematics and layout drawings
  • Check sheets for recording the works
  • Risk assessment
  • PPE assessment
  • Method statement
  • COSHH assessment 
  • Work permits etc

Cooling Tower Maintenance Checklist and Plan

Only Engineers and Operatives who are qualified, experienced, and fully understand the design and operation of the system should complete these inspections.

Below we run through an example of the checks that would generally be conducted, any observations should be noted, advice on the needs of the remedial work and, when completed signed off. The urgency of the remedial works will depend on the criticality of any observations.

Please note: Preventative Maintenance should not be confused with Inspecting and Cleaning of Cooling Towers which can be read about in our article 'Overview | Inspecting & Cleaning Cooling Towers'.

What to check daily

  • Unusual noise and vibrations in and around the tower, will generally be from the fan
  • Unusual noise and vibrations at the condenser water pump
  • Check the water level in the basin, this can be done via the level sensor at the BMS if part of the system
  • Water quality checks

What to check monthly

  • General overview of system condition inspection
  • The general condition of the fan and motor/drive mechanism
  • Check for oil leaks in components, hoses and fittings
  • Check oil levels and add if required
  • Clean the fan motor
  • The water makeup valve is operating correctly
  • Inspect and clean the air inlet
  • Inspect and clean the tower drift eliminators
  • Inspect and clean the tower fill pack
  • Inspect and clean the hot water basin feeding the fill pack
  • Inspect and clean the spray nozzles
  • Check the spray pattern of the nozzles
  • Inspect and clean the tower basin
  • Check operation of the blowdown system
  • Check operation of the bleed water valve and system
  • Check operation of vibration switch
  • Check and clean side stream filtration/sweeper systems
  • Check operation of the chemical dosing system
  • Check and clean pipework strainers
  • Manually check the level and valve of the tower water basin and make adjustments if required to the water feed
  • Check protective finishes to surfaces of tower and components to ensure are not damaged and compromised
  • Review operation of basin heater and clean sensor if necessary
  • Check the status of system operation [set to automatic]

 What to check quarterly [3 months]

  • Check belt alignment and tightness [if fitted to motor]
  • Check fan blades for cracks, missing balancing weights, and any apparent vibrations
  • Check fan blade pitch [angle]
  • Check fan blade tip clearance
  • Review operation/signal of level sensors and clean if necessary 
  • Inspect condition of ladders/handrails/stairways/walkways etc
Cooling Tower Pre-Functional Testing Checklist [MS Word] + [MS Excel]

Here is our open copy [MS Word] of the COOLING TOWER Pre-Functional Checklist, for making life a little easier...

We have also recently formatted this checklist to [MS Excel] and included it as a Bonus for FREE. 

So get an MS Word & MS Excel for the same price.


#CC: 049c

Buy Here | $1.99

Please do not underestimate the impact your purchase can have on this site; it allows us to re-invest in more content/resources, keeping those annoying banner adverts away.

What to check semi-annually [every 6 months]

  • Change oil
  • Check and tighten fan blade hub

What to check Yearly

  • Check all mounting bolts for tightness and signs of corrosion
  • Inspect all parts of the motor including oil plugs etc
  • Lubricate components
  • Inspect drive shaft not loose
  • Check for drive shaft/bush wear and tear
  • Check motor alignment on the fan

After any Extended Shutdown Checks

  • Complete all checks above

Cooling Tower Preventative Maintenance Sample Checklist [PDF] & [.doc]

To download the below document [Free] in A4-[.doc], click the below button to be taken to our shop:

FAQ

How do you clean a cooling tower?

see our article &#;Overview | Inspecting & Cleaning Cooling Towers&#;.

Evapco cooling tower maintenance checklist?

Here is a link to the Evapco checklist

The company is the world’s best hamon cooling towers supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.

SPX Marley cooling tower preventive maintenance checklist?

Here is a link to the SPX Marley checklist

&#; Latest Articles

&#; Author

If you would like to know more about the author, here is my Personal Linkedin Account

A Step-by-Step Cooling Tower Maintenance Checklist for ...

A Step-by-Step Cooling Tower Maintenance Checklist for Optimal Performance

Cooling towers play a crucial role in maintaining optimal temperatures for various industrial processes, including power generation, petrochemical, chemical, process and HVAC systems. These cooling towers are responsible for dissipating excess heat into the atmosphere. Like any mechanical system, cooling towers demand regular maintenance to ensure their longevity and efficiency. Importantly, neglecting maintenance can lead to decreased efficiency, costly repairs, and potential safety hazards. This blog post contains a simple and comprehensive step-by-step cooling tower maintenance checklist that will help you keep your cooling tower operating efficiently and smoothly.

This useful checklist will help you gain valuable insights into maintaining your cooling tower, maximizing its performance, and extending its lifespan. Let&#;s dive in and explore the essential steps to keep your cooling tower maintenance checklist to see if it is running smoothly and efficiently.

What is a Cooling Tower?

A cooling tower is a large, open-air device designed to cool process hot water or other fluids by extracting the heat and releasing it into the atmosphere. Cooling towers can be forced draft, induced draft or natural draft and can be found in industrial & power plants, refineries, and even large commercial buildings.

Understanding the Key Components

A cooling tower consists of the following main elements:

  1. Fan System: Responsible for creating the airflow necessary for heat dissipation.
  2. Drift Eliminators: These specialized components prevent water droplets from being carried away by the exhaust air.
  3. Fill Material: It facilitates heat transfer by maximizing contact between air and water, promoting efficient cooling.
  4. Water Distribution System: Distributes water evenly across the fill material to ensure optimal cooling efficiency.
  5. Basin and Sump: The basin collects and holds water for recirculation, while the sump allows for proper drainage.A Step-by-Step Cooling Tower Maintenance Checklist

Regular maintenance of cooling towers is vital for their efficient operation and longevity. Here is the step-by-step checklist, that can help keep your cooling tower in optimal condition. So check out the below steps.

Step 1: Inspect the Tower Exterior

Start by conducting a visual inspection of the cooling tower&#;s exterior. Look for any signs of physical damage, corrosion, or leaks. Check the structural integrity, fan blades, louvers, and access doors. If you spot any issues, make a note for further investigation or repair. Is the water flow even across the entire &#;rain zone&#;? If not, you know there&#;s a possibility of broken nozzles, clogged fill or other issues of concern.

Step 2: Clean the Basin and Sump

The cooling tower is a highly effective air scrubber so the cooling tower&#;s cold water basin and sump are susceptible to debris buildup, sediment, and microbiological growth. Begin by draining and cleaning the basin thoroughly. Remove any accumulated dirt, leaves, or other foreign objects. Use a suitable biocide or cleaning agent to eliminate bacteria, algae, and fungi that can lead to fouling and reduced performance.

Step 3: Check the Water Treatment System

Proper water treatment is essential to prevent scale, corrosion, and biological growth within the cooling tower system. Inspect the water treatment equipment, including chemical feeders, filters, and pH control systems. Ensure that the equipment is functioning correctly, and adjust chemical dosing rates as needed.

Step 4: Examine Drift Eliminators and Fill Material

Drift eliminators and fill material play vital roles in optimizing the cooling tower&#;s efficiency. Inspect these components for any blockages, obstructions, or signs of wear and tear. Clear any debris or scaling from the drift eliminators and ensure that the fill material is intact and evenly distributing water throughout each cell.

Step 5: Check the Fan System

The fan system is crucial for proper airflow and heat dissipation. Inspect the blades of fan for any damage or imbalance. Verify that the fan motor, coupling and gearbox are in good condition and properly aligned. Lubricate bearings and change gearbox oil as recommended by the manufacturer.

Step 6: Inspect the Water Distribution System

The water distribution system ensures even water flows over the fill material. Check for clogged or malfunctioning spray nozzles. Adjust or replace any faulty nozzles to maintain consistent water distribution and prevent dry spots which cause inefficient cooling.

Step 7: Clean and Inspect the Water Piping

Examine the water piping system for leaks, corrosion, or blockages. Remove any scale or deposits that may have accumulated. Check valves, fittings, and couplings for proper operation and tightness. Repair or replace any damaged components as necessary.

Step 8: Test Water Quality

Regular water quality testing is crucial to monitor parameters such as pH, conductivity, and total dissolved solids (TDS). Collect water samples and conduct tests using appropriate testing kits or send them to a certified laboratory. Moreover, adjust water treatment parameters based on the results to maintain optimal conditions.

Step 9: Document and Schedule Maintenance Tasks

Keep detailed records of all maintenance activities, including inspections, repairs, and water treatment adjustments. Create a maintenance schedule based on the manufacturer&#;s recommendations and your observations. Thus, regularly review and update the schedule to ensure timely and proactive maintenance.

Comprehensive Cooling Tower Maintenance Checklist: From Daily Checks to Annual Inspections

Daily

  • Check for any visible leaks, unusual noises, or vibrations.
  • Inspect the water level and ensure it&#;s within the recommended range.
  • Monitor water temperature and pressure gauges.
  • Check fan operation and ensure proper operation.
  • walk the perimeter of the tower to inspect balance in the rain zone.w

Quarterly

  • Conduct a thorough inspection of the tower&#;s exterior, including structural integrity, fan blades, and louvers.
  • Check and clean water strainers or filters.
  • Inspect and lubricate fan motor bearings and gearbox oil levels & condition..
  • Test water quality parameters such as pH, conductivity, and TDS.

Semi Annually

  • Conduct a comprehensive inspection of the water distribution system, including pipes, valves, and fittings.
  • Inspect fill material for any signs of damage or fouling.
  • Verify alignment couplings in the fan system.
  • Clean or replace any clogged or damaged spray nozzles.

Annually

  • Perform a detailed inspection of the entire cooling tower system, including mechanical and electrical components.
  • check fan blades for cracks, balance and alignment.
  • weigh selected fill blocks from lower levels & record weights to measure fouling.
  • Inspect and clean water basins and sumps.
  • Check and adjust the water treatment system, including chemical feeders and control equipment.
  • Conduct a thorough cleaning and inspection of water piping and associated equipment.

Preparing the Cooling Tower for Non-Operational Periods

Before shutting down the cooling tower for an extended period, it&#;s crucial to take the following steps:

Thorough Cleaning

Clean the entire cooling tower system, including the basin, sump, fill material, and water distribution system. Remove any debris, sediment, or biological growth that may have accumulated. This helps prevent corrosion, fouling, and the proliferation of harmful microorganisms.

Drain the System

Completely drain the cooling tower system to remove all water. This minimizes the risk of stagnant water, which can lead to bacterial growth, scale formation, and corrosion. Ensure that the system is dry and free of moisture before proceeding.

Inspect and Repair

Conduct a comprehensive inspection of the cooling tower components. Look for any signs of damage, such as cracks, leaks, or worn-out parts. Address and repair these issues before the idle period to prevent further deterioration.

The Importance of Preventative Maintenance

Like any mechanical system, cooling towers require regular maintenance to ensure their efficiency and longevity. Following, we explore why their preventative maintenance is of utmost importance.

Efficiency and Performance

Regular maintenance ensures that towers continue to operate at peak efficiency. Over time, mineral deposits, sediment, and biological growth can accumulate within the tower, hindering heat transfer. This reduces the cooling capacity and overall performance of the tower. By conducting routine inspections, cleaning, and preventive maintenance, these issues can be identified and addressed promptly, allowing the tower to function optimally.

Preventing Equipment Damage

Cooling towers are interconnected with expensive and critical machinery. Neglecting maintenance can lead to severe consequences, such as equipment failure, plant downtime, and costly repairs. For example, untreated water in the tower can cause corrosion and fouling in the system, leading to more serious damage to the overall system. Routine maintenance, including water treatment and corrosion control measures, helps safeguard the entire cooling system, ensuring its longevity and uninterrupted operation.

Ensuring Regulatory Compliance

Many countries have specific regulations and guidelines in place to ensure the safe operation of cooling towers, particularly regarding water quality and emissions. Regular maintenance plays a crucial role in meeting these compliance standards. By conducting routine inspections, monitoring water chemistry, and implementing necessary modifications, companies can avoid penalties, legal complications, and negative impacts on their reputation.

Energy Efficiency and Cost Savings

Well-maintained towers consume less energy, resulting in substantial cost savings for industries. A fouled or poorly maintained tower requires more power to achieve the desired cooling effect, increasing energy consumption and utility bills. Regular maintenance, including cleaning of heat exchange surfaces and optimizing water treatment, helps maintain efficient heat transfer, reducing energy usage, and lowering operational costs.

Health and Environmental Concerns

Neglected cooling towers can transform into ideal breeding grounds for harmful bacteria, including the notorious Legionella, thereby endangering human health. However, implementing routine maintenance practices, such as regular disinfection and monitoring of water quality, can effectively prevent or control the growth of bacteria and other microorganisms. By prioritizing these maintenance measures, not only can safe working surroundings be ensured for employees but also the surrounding ecosystem can be shielded from potential contamination.

In any industrial or commercial setting, cooling towers play a vital role in regulating temperatures and maintaining equipment efficiency. However, these structures can inadvertently become a haven for harmful bacteria when neglected. Among the most concerning bacteria is Legionella, which can cause severe respiratory illnesses when inhaled.

To combat this issue, routine maintenance is paramount. By incorporating regular disinfection protocols and diligently monitoring water quality, the growth and proliferation of bacteria and other microorganisms can be proactively managed. This preventive approach significantly reduces the risk of infections and safeguards the well-being of employees and anyone exposed to the cooling tower environment.

Therefore, cooling tower maintenance is not just an optional task; it is a critical aspect of ensuring operational efficiency, protecting equipment, complying with regulations, and safeguarding the environment.

Conclusion

Following a step-by-step cooling tower maintenance checklist will help you keep your cooling tower in optimal condition, ensuring efficient heat dissipation and preventing costly breakdowns. Regular inspections, cleaning, and adjustments will prolong the lifespan of your cooling tower, save energy, and maintain the reliability of your industrial processes. By investing time and effort in proper cooling tower maintenance, you&#;ll enjoy long-term benefits in terms of performance, cost savings, and uninterrupted operations.

Regular maintenance efforts, regardless of the frequency, will help you extend the lifespan of your cooling tower, optimize energy consumption, prevent breakdowns, and ensure efficient heat dissipation. Invest in proper cooling tower maintenance to enjoy the benefits of cost savings, improved system performance, and uninterrupted operations.

Keep Your Cooling Tower at Its Best: Partner with ICS Professionals Today

Maintaining your cooling tower is crucial for its optimal performance, and the experts at ICS are here to help. Our skilled professionals are well-equipped to handle all aspects of cooling tower maintenance. From routine inspections to thorough cleaning and necessary repairs, we&#;ve got you covered.

Trust us to keep your cooling tower running efficiently, ensuring a comfortable and safe environment. Contact ICS today and let our team of experts assist you in maintaining your cooling tower&#;s peak performance.

FAQs About Cooling Tower Maintenance

How frequently should cooling tower maintenance be performed?

The frequency of cooling tower maintenance depends on numerous factors, including the type of cooling tower, its age, usage intensity, and environmental conditions. In general, cooling towers should undergo routine maintenance at least twice a year. However, in locations with harsher climates or higher levels of contamination, more frequent maintenance may be necessary. Regular inspections and monitoring will determine the specific maintenance schedule required for each cooling tower.

What are the common tasks included in a cooling tower maintenance checklist?

A typical cooling tower maintenance checklist includes tasks such as cleaning and disinfection of tower fill, drift eliminators, and basins; inspection and lubrication of mechanical components like fans, motors, and gearboxes; testing and adjusting water chemical parameters; and inspecting structural elements for signs of corrosion or damage. It may also involve reviewing operational data, verifying control settings, and conducting thermal performance evaluations.

Can cooling tower maintenance prevent Legionella bacteria growth?

Yes, regular cooling tower maintenance is essential in preventing the growth and spread of Legionella bacteria, which can cause Legionnaires&#; disease. By keeping cooling towers clean, eliminating biofilm, maintaining proper water treatment, and ensuring adequate disinfection, the risk of Legionella contamination can be significantly reduced. Compliance with water quality standards and routine testing are crucial aspects of cooling tower maintenance for Legionella control.

Are you interested in learning more about wet cooling tower diagram? Contact us today to secure an expert consultation!